Get free alertsFree alerts

How to win electrical testing and gas servicing contracts with councils and housing associations

Last reviewed 28 October 2026. General guidance, not legal advice.

On this page (14 parts)
  1. What these buyers need
  2. Electrical checks in social housing
  3. Work to the current BS 7671
  4. Gas safety checks
  5. Awaab's Law and response times
  6. Decent Homes Standard and energy targets
  7. Heat pumps and the Warm Homes: Social Housing Fund
  8. School and public building plant
  9. Legionella and water hygiene
  10. Registrations that win this work
  11. How this work is bought
  12. Practical steps
  13. Frequently asked questions
  14. Sources

This guide is for small electrical, gas, heating and plumbing firms that want compliance and heating work from councils, housing associations and schools. It covers the rules that create the work, the registrations buyers check and how to prepare. Most rules here apply in England.

Key points

What these buyers need

Work Examples Registration that matters
Electrical inspection (EICR) Fixed wiring in homes, blocks and public buildings Qualified electricians; scheme membership often requested
Appliances and PAT Equipment provided with tenancies, or used in schools and offices Competent tester
Emergency lighting Monthly and annual tests Competent person
Gas safety and servicing Annual landlord checks, boiler servicing, breakdowns Gas Safe, with the right categories
Heating replacement Boilers and systems in planned programmes Gas Safe
Heat pumps and retrofit Heat pumps, solar PV, insulation on funded schemes MCS, TrustMark, PAS 2030
School and public building plant Commercial boilers, controls, fixed wiring Non-domestic gas qualifications
Water hygiene Legionella risk assessment, temperature checks Competent person or specialist firm

For how housing associations buy more widely, see our housing association guide.

Electrical checks in social housing

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 were extended to social housing in 2025. Government guidance says they apply to social tenancies granted after 1 December 2025, and to older tenancies from 1 May 2026, with first checks on those due before 1 November 2026.

The landlord must:

C1 and C2 codes need remedial work and FI needs investigating. C3 does not need remedial work.

The guidance defines a qualified person as someone competent to do the work. It does not require scheme membership, and points landlords to the Registered Competent Person Electrical register.

After the first round, landlords need a rolling 5-year programme, quick remedial follow-up and reports on time. Show you can do all three.

Work to the current BS 7671

BSI and the IET published Amendment 4 to BS 7671 on 15 April 2026. BSI says the previous version (BS 7671:2018+A2:2022+A3:2024) was withdrawn on 15 October 2026, and the IET says Amendment 2 should no longer be used for new work or certification. Check your team, certificates and software reflect BS 7671:2018+A4:2026.

Gas safety checks

Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires landlords to keep gas fittings and flues they provide safe, and to have each one checked within 12 months of installation and then at least every 12 months. The record must list each appliance checked, any defects and action taken, and the engineer's name, signature and registration number. HSE says existing tenants get a copy within 28 days and new tenants before moving in. A check up to 2 months early keeps the original deadline.

Gas work in Great Britain must be done by a business on the Gas Safe Register. Each engineer's ID card lists the work they are qualified for, and commercial boilers in schools and offices need non-domestic qualifications. Check your categories before you bid.

The landlord's deadline does not move when a tenant is out, so be ready to explain how you book visits and follow up failed ones.

Alarms. Since 1 October 2022, social landlords in England must have a smoke alarm on each storey used as living accommodation and a carbon monoxide alarm in each room with a fixed combustion appliance (except gas cookers), and must repair or replace faulty alarms. This work can sit inside gas or electrical contracts.

Awaab's Law and response times

Awaab's Law has covered damp and mould and emergency hazards in social housing in England since 27 October 2025. Phase 2 regulations, laid on 13 July 2026, apply from 30 November 2026 and add hazards including excess cold, fire and explosions, and electrical hazards. Emergency hazards must be dealt with within 24 hours.

Government guidance lists gas or carbon monoxide leaks, broken boilers and exposed wiring as possible emergency hazards. It says electrical hazards should be investigated and fixed by a qualified, competent electrician, and gives temporary heaters while a boiler is fixed as an example of interim safety work. A final phase is due in 2027. Expect faster call-out times and duties to report what you find. Our housing association guide sets out the full timescales.

Decent Homes Standard and energy targets

The government's January 2026 policy statement says the new Decent Homes Standard will apply from 2035. Heating and electrical systems are "key" components that must not be dangerous, the electrical system must be inspected and tested at least every 5 years, and the main heating must heat the whole home. The statement also says social rented homes must reach EPC C or equivalent by 1 April 2030, with some measurement detail still to be finalised.

Heat pumps and the Warm Homes: Social Housing Fund

This fund gives grants to social landlords to make homes warmer and cheaper to heat. Wave 3 was originally allocated £1.29 billion for April 2025 to March 2028, with just under £1.15 billion offered across 138 projects. Landlords must at least match the grant, and the Warm Homes Plan added £295 million for 2026 to 2027.

The June 2026 guidance addendum says:

To get MCS certified, you apply to a certification body that assesses a site installation and your processes. MCS says you need at least one fully compliant installation for each technology.

Government publishes the list of funded landlords. Find the ones near you, then ask who is delivering their programme: working for that contractor may be quicker than bidding yourself. See subcontracting on public contracts.

School and public building plant

DfE's estate guidance says it is good practice to have gas appliances and pipework checked at least once a year, and that all electrical testing must be done by a suitably qualified electrician, at a frequency based on risk. It cites a CIPFA good practice split of about 70:30 between planned and reactive maintenance budgets.

For how schools buy, see our school and academy guide.

Legionella and water hygiene

HSE says landlords must assess legionella risk, with guidance in the L8 Approved Code of Practice and HSG274. For domestic water systems, sampling is generally not needed and temperature monitoring is a reliable check. In schools, DfE says duty holders must appoint a competent person, follow a written control scheme and keep records.

Registrations that win this work

Registration Covers Legal or requested
Gas Safe Register Gas work Legal
NICEIC or ELECSA (both Certsure), NAPIT Electrical work Requested
OFTEC Oil heating Requested
HETAS Solid fuel and biomass Requested
MCS, TrustMark, PAS 2030 Heat pumps, solar, retrofit Required on funded schemes

GOV.UK says competent person schemes let installers self-certify certain building work instead of getting building regulations approval. Where a buyer names a particular scheme, say if you hold an equivalent and show why it is equivalent. See accreditations by trade (including F gas for heat pumps) and health and safety accreditations.

How this work is bought

Councils and housing associations use their own tenders, frameworks, dynamic markets and approved lists, and many large contracts go to a main contractor who subcontracts. In England, a council advertising a below-threshold contract worth £30,000 or more including VAT must post a notice on Find a Tender first. See procurement thresholds in 2026 and frameworks, DPS and dynamic markets.

Outside England, gas safety law covers Great Britain (Northern Ireland has its own), but the electrical, Awaab's Law, Decent Homes and Warm Homes rules above are for England.

Practical steps

  1. Match your registrations to the work, including domestic and non-domestic gas categories.
  2. Work and certify to BS 7671:2018+A4:2026.
  3. Build an evidence pack: a sample EICR and gas safety record, report turnaround times and your 28-day remedial process.
  4. Write down how you book access and handle failed visits.
  5. Plan for Awaab's Law: out-of-hours cover, temporary heating and hazard reporting.
  6. For retrofit work, start MCS and TrustMark early.
  7. Join dynamic markets and approved lists, and contact main contractors.

BidTrowel lists open electrical, heating and plumbing contracts at /tenders/mechanical-electrical/ and can email you new ones.

Frequently asked questions

Do I need NICEIC to do EICRs for social landlords?

No. Government guidance says a qualified person is someone competent to do the work. Buyers often ask for scheme membership or an equivalent.

How often do social landlords need gas safety checks?

At least every 12 months for each appliance and flue they provide, by a Gas Safe registered engineer.

Is annual PAT testing a legal requirement?

No. HSE says equipment must be kept safe, with testing based on risk.

Can I fit heat pumps on Warm Homes projects without MCS?

No. The scheme guidance says installers must be MCS certified in all cases for relevant measures.

This guide is general information, not legal advice.

Sources

Get public contracts that fit your firm by email. Free: every weekday for your first two weeks, then Mondays when there are new matches.

Get free alerts