How to win electrical testing and gas servicing contracts with councils and housing associations
On this page (14 parts)
- What these buyers need
- Electrical checks in social housing
- Work to the current BS 7671
- Gas safety checks
- Awaab's Law and response times
- Decent Homes Standard and energy targets
- Heat pumps and the Warm Homes: Social Housing Fund
- School and public building plant
- Legionella and water hygiene
- Registrations that win this work
- How this work is bought
- Practical steps
- Frequently asked questions
- Sources
This guide is for small electrical, gas, heating and plumbing firms that want compliance and heating work from councils, housing associations and schools. It covers the rules that create the work, the registrations buyers check and how to prepare. Most rules here apply in England.
Key points
- Social landlords in England must have each home's electrical installation inspected and tested at least every 5 years. First checks on tenancies granted before 1 December 2025 are due before 1 November 2026.
- Landlords must have a gas safety check every 12 months on the appliances and flues they provide, by a Gas Safe registered engineer.
- The current wiring regulations are BS 7671:2018+A4:2026. The previous version was withdrawn on 15 October 2026.
- From 30 November 2026, Awaab's Law covers electrical hazards, excess cold, and fire and explosions.
- Heat pumps funded by the Warm Homes: Social Housing Fund must be fitted by MCS certified, TrustMark registered installers.
What these buyers need
| Work | Examples | Registration that matters |
|---|---|---|
| Electrical inspection (EICR) | Fixed wiring in homes, blocks and public buildings | Qualified electricians; scheme membership often requested |
| Appliances and PAT | Equipment provided with tenancies, or used in schools and offices | Competent tester |
| Emergency lighting | Monthly and annual tests | Competent person |
| Gas safety and servicing | Annual landlord checks, boiler servicing, breakdowns | Gas Safe, with the right categories |
| Heating replacement | Boilers and systems in planned programmes | Gas Safe |
| Heat pumps and retrofit | Heat pumps, solar PV, insulation on funded schemes | MCS, TrustMark, PAS 2030 |
| School and public building plant | Commercial boilers, controls, fixed wiring | Non-domestic gas qualifications |
| Water hygiene | Legionella risk assessment, temperature checks | Competent person or specialist firm |
For how housing associations buy more widely, see our housing association guide.
Electrical checks in social housing
The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 were extended to social housing in 2025. Government guidance says they apply to social tenancies granted after 1 December 2025, and to older tenancies from 1 May 2026, with first checks on those due before 1 November 2026.
The landlord must:
- have the installation inspected and tested by a qualified person at least every 5 years
- have electrical equipment it provides, such as cookers and fridges, checked too
- give an existing tenant the report within 28 days, and a new tenant before they move in
- finish remedial work within 28 days, or sooner if the report says so, then send the tenant and council written confirmation from the qualified person
C1 and C2 codes need remedial work and FI needs investigating. C3 does not need remedial work.
The guidance defines a qualified person as someone competent to do the work. It does not require scheme membership, and points landlords to the Registered Competent Person Electrical register.
After the first round, landlords need a rolling 5-year programme, quick remedial follow-up and reports on time. Show you can do all three.
Work to the current BS 7671
BSI and the IET published Amendment 4 to BS 7671 on 15 April 2026. BSI says the previous version (BS 7671:2018+A2:2022+A3:2024) was withdrawn on 15 October 2026, and the IET says Amendment 2 should no longer be used for new work or certification. Check your team, certificates and software reflect BS 7671:2018+A4:2026.
Gas safety checks
Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires landlords to keep gas fittings and flues they provide safe, and to have each one checked within 12 months of installation and then at least every 12 months. The record must list each appliance checked, any defects and action taken, and the engineer's name, signature and registration number. HSE says existing tenants get a copy within 28 days and new tenants before moving in. A check up to 2 months early keeps the original deadline.
Gas work in Great Britain must be done by a business on the Gas Safe Register. Each engineer's ID card lists the work they are qualified for, and commercial boilers in schools and offices need non-domestic qualifications. Check your categories before you bid.
The landlord's deadline does not move when a tenant is out, so be ready to explain how you book visits and follow up failed ones.
Alarms. Since 1 October 2022, social landlords in England must have a smoke alarm on each storey used as living accommodation and a carbon monoxide alarm in each room with a fixed combustion appliance (except gas cookers), and must repair or replace faulty alarms. This work can sit inside gas or electrical contracts.
Awaab's Law and response times
Awaab's Law has covered damp and mould and emergency hazards in social housing in England since 27 October 2025. Phase 2 regulations, laid on 13 July 2026, apply from 30 November 2026 and add hazards including excess cold, fire and explosions, and electrical hazards. Emergency hazards must be dealt with within 24 hours.
Government guidance lists gas or carbon monoxide leaks, broken boilers and exposed wiring as possible emergency hazards. It says electrical hazards should be investigated and fixed by a qualified, competent electrician, and gives temporary heaters while a boiler is fixed as an example of interim safety work. A final phase is due in 2027. Expect faster call-out times and duties to report what you find. Our housing association guide sets out the full timescales.
Decent Homes Standard and energy targets
The government's January 2026 policy statement says the new Decent Homes Standard will apply from 2035. Heating and electrical systems are "key" components that must not be dangerous, the electrical system must be inspected and tested at least every 5 years, and the main heating must heat the whole home. The statement also says social rented homes must reach EPC C or equivalent by 1 April 2030, with some measurement detail still to be finalised.
Heat pumps and the Warm Homes: Social Housing Fund
This fund gives grants to social landlords to make homes warmer and cheaper to heat. Wave 3 was originally allocated £1.29 billion for April 2025 to March 2028, with just under £1.15 billion offered across 138 projects. Landlords must at least match the grant, and the Warm Homes Plan added £295 million for 2026 to 2027.
The June 2026 guidance addendum says:
- all installers must be TrustMark registered, and measures lodged on the TrustMark Retrofit Portal
- projects must follow PAS 2035:2023, with energy efficiency measures installed by PAS 2030 certified installers
- installers must be MCS certified in all cases for relevant measures, such as heat pumps and solar
- grant must be spent by 31 March 2028, though landlords can keep delivering with their own funding until March 2030
To get MCS certified, you apply to a certification body that assesses a site installation and your processes. MCS says you need at least one fully compliant installation for each technology.
Government publishes the list of funded landlords. Find the ones near you, then ask who is delivering their programme: working for that contractor may be quicker than bidding yourself. See subcontracting on public contracts.
School and public building plant
DfE's estate guidance says it is good practice to have gas appliances and pipework checked at least once a year, and that all electrical testing must be done by a suitably qualified electrician, at a frequency based on risk. It cites a CIPFA good practice split of about 70:30 between planned and reactive maintenance budgets.
- PAT. HSE says the law does not require portable appliances to be tested every year. It requires equipment to be kept safe, with risk-based testing.
- Emergency lighting. The Fire Protection Association says escape lighting is a legal requirement for business premises, with monthly function tests and an annual three-hour test by a competent person, to BS 5266-1.
For how schools buy, see our school and academy guide.
Legionella and water hygiene
HSE says landlords must assess legionella risk, with guidance in the L8 Approved Code of Practice and HSG274. For domestic water systems, sampling is generally not needed and temperature monitoring is a reliable check. In schools, DfE says duty holders must appoint a competent person, follow a written control scheme and keep records.
Registrations that win this work
| Registration | Covers | Legal or requested |
|---|---|---|
| Gas Safe Register | Gas work | Legal |
| NICEIC or ELECSA (both Certsure), NAPIT | Electrical work | Requested |
| OFTEC | Oil heating | Requested |
| HETAS | Solid fuel and biomass | Requested |
| MCS, TrustMark, PAS 2030 | Heat pumps, solar, retrofit | Required on funded schemes |
GOV.UK says competent person schemes let installers self-certify certain building work instead of getting building regulations approval. Where a buyer names a particular scheme, say if you hold an equivalent and show why it is equivalent. See accreditations by trade (including F gas for heat pumps) and health and safety accreditations.
How this work is bought
Councils and housing associations use their own tenders, frameworks, dynamic markets and approved lists, and many large contracts go to a main contractor who subcontracts. In England, a council advertising a below-threshold contract worth £30,000 or more including VAT must post a notice on Find a Tender first. See procurement thresholds in 2026 and frameworks, DPS and dynamic markets.
Outside England, gas safety law covers Great Britain (Northern Ireland has its own), but the electrical, Awaab's Law, Decent Homes and Warm Homes rules above are for England.
Practical steps
- Match your registrations to the work, including domestic and non-domestic gas categories.
- Work and certify to BS 7671:2018+A4:2026.
- Build an evidence pack: a sample EICR and gas safety record, report turnaround times and your 28-day remedial process.
- Write down how you book access and handle failed visits.
- Plan for Awaab's Law: out-of-hours cover, temporary heating and hazard reporting.
- For retrofit work, start MCS and TrustMark early.
- Join dynamic markets and approved lists, and contact main contractors.
BidTrowel lists open electrical, heating and plumbing contracts at /tenders/mechanical-electrical/ and can email you new ones.
Frequently asked questions
Do I need NICEIC to do EICRs for social landlords?
No. Government guidance says a qualified person is someone competent to do the work. Buyers often ask for scheme membership or an equivalent.
How often do social landlords need gas safety checks?
At least every 12 months for each appliance and flue they provide, by a Gas Safe registered engineer.
Is annual PAT testing a legal requirement?
No. HSE says equipment must be kept safe, with testing based on risk.
Can I fit heat pumps on Warm Homes projects without MCS?
No. The scheme guidance says installers must be MCS certified in all cases for relevant measures.
This guide is general information, not legal advice.
Sources
- GOV.UK: Electrical safety standards in the private and social rented sectors: guidance (checked 28 October 2026)
- legislation.gov.uk: Electrical Safety Standards in the Private Rented Sector (England) (Amendment) (Extension to the Social Rented Sector) Regulations 2025 (checked 28 October 2026)
- Browne Jacobson: Mandatory electrical safety checks for social housing tenancies (checked 28 October 2026)
- BSI: BS 7671:2018+A4:2026, get the latest amendment to the UK's wiring regulations (checked 28 October 2026)
- IET: Amendment 4 updates to the 18th Edition (checked 28 October 2026)
- Electrical Contracting News: NICEIC responds to BS 7671 Amendment 4 (checked 28 October 2026)
- legislation.gov.uk: Gas Safety (Installation and Use) Regulations 1998, Part F (checked 28 October 2026)
- HSE: Gas safety record (checked 28 October 2026)
- Somerset Council: Gas safety in your business (checked 28 October 2026)
- GOV.UK: The Smoke and Carbon Monoxide Alarm (England) Regulations 2015: Q&A booklet (checked 28 October 2026)
- GOV.UK: Awaab's Law Phase 2: guidance for social landlords (checked 28 October 2026)
- GOV.UK: Safer homes for 4m tenants with quicker action on dangerous homes (checked 28 October 2026)
- CIH: Second phase of Awaab's Law laid before Parliament (checked 28 October 2026)
- GOV.UK: The New Decent Homes Standard: policy statement (checked 28 October 2026)
- GOV.UK: Warm Homes: Social Housing Fund Wave 3: successful social housing landlords (checked 28 October 2026)
- DESNZ: Warm Homes: Social Housing Fund Wave 3 scheme guidance addendum, June 2026 (PDF) (checked 28 October 2026)
- MCS: Becoming certified (checked 28 October 2026)
- GOV.UK: Competent person scheme: current schemes and how schemes are authorised (checked 28 October 2026)
- UK Parliament: Written evidence from Certsure LLP (checked 28 October 2026)
- GOV.UK: Good estate management for schools: maintaining your estate (checked 28 October 2026)
- GOV.UK: Good estate management for schools: health and safety (checked 28 October 2026)
- HSE: PAT, portable appliance testing FAQs (checked 28 October 2026)
- Fire Protection Association: How to test emergency lighting (checked 28 October 2026)