This guide is for owners of small fire protection and security firms who want maintenance contracts from councils, housing associations, the NHS, schools and universities. It covers the law behind the work, servicing intervals, the certification buyers ask for, police response, CCTV rules and what a strong bid shows.
Key points
- Under the Fire Safety Order, the responsible person must keep fire safety equipment under a suitable system of maintenance. That duty drives term contracts for alarms, lighting, extinguishers, doors and risers.
- In England, communal fire doors in residential buildings over 11 metres must be checked at least every 3 months, and flat entrance doors (with best endeavours) at least every 12 months.
- BS 5839-1:2025 sets fire alarm service visits at about every 6 months, with any visit between 5 and 7 months after the last one acceptable.
- Third-party certification such as BAFE, NSI or SSAIB is not a legal requirement, but buyers often ask for it, or an equivalent.
- Police response to an intruder alarm depends on a unique reference number (URN) issued under National Police Chiefs' Council (NPCC) requirements.
Why public buyers keep buying this work
The Regulatory Reform (Fire Safety) Order 2005 (the Fire Safety Order) applies in England and Wales. Article 17 says that, where needed to keep people safe, the responsible person must ensure premises, facilities, equipment and devices are "subject to a suitable system of maintenance" and kept "in efficient working order and in good repair". Scotland and Northern Ireland have their own fire safety rules.
Since 1 October 2023, changes made by section 156 of the Building Safety Act 2022 mean every responsible person must record the full fire risk assessment and their fire safety arrangements. Anyone appointed to help with it must be competent, and their name must be recorded.
In England, the Fire Safety (England) Regulations 2022 came into force on 23 January 2023. They added two duties that create regular work in blocks of flats:
- Fire doors (regulation 10). In buildings with two or more homes and above 11 metres, communal fire doors must be checked at least every 3 months and flat entrance doors at least every 12 months, including checking self-closers work. Government guidance says these basic checks do not need a specialist, but repairs and replacements must be done by a competent person.
- Lifts and firefighting equipment (regulation 7). In high-rise residential buildings (at least 18 metres or 7 storeys), monthly checks cover firefighting lifts and "essential fire-fighting equipment", including dry and wet risers, smoke control, suppression systems, alarm systems in common parts and evacuation alert systems.
The same height test (at least 18 metres or 7 storeys, with at least 2 residential units) defines a higher-risk building under the Building Safety Act 2022. Our housing association guide explains what that means for landlords.
What gets serviced, and how often
| System | Routine checks and servicing | Where it comes from |
|---|---|---|
| Fire alarms | Weekly test by the site using a different call point each week; service about every 6 months (5 to 7 months acceptable) | Government small premises guide; BS 5839-1:2025 |
| Emergency lighting | Monthly functional test; annual inspection and test by a competent contractor | Government small premises guide; BS 5266-1 |
| Extinguishers | Monthly visual check by the site; basic service every 12 months; extended service every 5 years for water and powder; overhaul every 10 years for CO2 | BS 5306-3, as summarised by BAFE |
| Fire doors (flats over 11 m) | Communal doors every 3 months; flat entrance doors every 12 months | Fire Safety (England) Regulations 2022 |
| Firefighting equipment (flats 18 m or 7 storeys and over) | Monthly checks, on top of normal maintenance | Fire Safety (England) Regulations 2022 |
BS 5839-1:2025 also adds a clause on remote services and cyber security. The 2025 revision of BS 5266-1 says photometric performance should be verified at least every five years.
For intruder alarms, CCTV and access control, the contract and the system's standards usually set the servicing.
Who buys, and how they buy
- Councils buy for their own buildings and any council homes. In England, a council that advertises a job worth £30,000 or more including VAT must publish a notice on Find a Tender first. See our guide to procurement thresholds in 2026.
- Housing associations buy fire door checks, alarm and lighting servicing and risers for blocks of flats, often through frameworks or approved lists.
- NHS trusts count as central government for thresholds, so their notice figure is £12,000. NHS fire detection guidance (HTM 05-03 Part B) encourages healthcare bodies to use companies assessed by a UKAS-accredited certification body, naming BAFE SP203-1 and LPCB.
- Schools often use frameworks the Department for Education lists. See our school and academy contracts guide.
- Universities buy directly and through purchasing consortiums.
Recent examples:
- The University of Strathclyde in Glasgow (under Scottish procurement rules) tendered a fire alarm, voice evacuation and extinguishing systems maintenance contract (2025 to 2029) in two lots worth about £1.35 million excluding VAT. It asked for BAFE plus NSI Gold or BSIA membership (or equivalent), a 4-hour maximum fault response and £10 million employer's and public liability cover, and scored 70% price, 30% quality.
- Royal Holloway, University of London, published a market engagement notice for a 5-year CCTV, access control and intruder alarm maintenance contract estimated at £1.5 million including VAT, marked as suitable for SMEs.
- A North East Universities Purchasing Consortium fire safety framework, open to Crescent Purchasing Consortium members, has four lots with six suppliers on each, including one for fire equipment supply and maintenance.
Lots like these give a small extinguisher or alarm firm a realistic way in. Our guide to frameworks, DPS and dynamic markets explains how to get on these lists.
The certification buyers ask for
| Work | Schemes buyers may ask for |
|---|---|
| Fire alarms | BAFE SP203-1 (covers design, installation, commissioning and maintenance) |
| Emergency lighting | BAFE SP203-4 |
| Extinguishers | BAFE SP101 |
| Dry and wet risers | BAFE SP105 |
| Fire risk assessment | BAFE SP205 for companies; individual registers such as the IFE Fire Risk Assessors Register |
| Fire doors | FDIS for inspectors; BM TRADA Q-Mark fire door maintenance and installation; IFC Certification installer schemes |
| Passive and active fire protection installers | FIRAS (Warringtonfire) |
| Sprinklers | LPCB LPS 1048 |
| Intruder alarms, CCTV, access control | NSI Gold or Silver; SSAIB |
- None of these is a legal requirement, but a buyer can make one, or an equivalent, a condition. Where a buyer names a scheme and you hold an equivalent, say so and show why it is equivalent. See accreditations by trade.
- NSI Silver is designed as a stepping stone to NSI Gold, with the same technical requirements. Gold adds an ISO 9001 quality management system.
- FDIS says it became, in March 2026, the first UK scheme with UKAS accreditation for certifying individual fire door inspectors.
- BS 8674:2025 is a code of practice, published in August 2025, setting out three levels of competence for individual fire risk assessors (Foundation, Intermediate and Advanced). It is not a legal requirement, but a buyer may ask about it.
Most buyers will also want health and safety accreditation. See SSIP and CHAS.
Intruder alarms and police response
The NPCC policy is called Police Operational Advice and Security Industry Requirements for Response to Security Systems, most recently updated in May 2025. A police force gives each qualifying system a URN, which flags the premises for police response when a verified alarm signal comes in.
NSI says a system must be installed, maintained and monitored by NSI approved companies to be eligible, and SSAIB says its certification supports URN applications. Police can withdraw response when false alarms reach an unacceptable level: West Yorkshire Police gives three false calls in a rolling 12 months as an example. So show buyers how you keep false alarms down.
CCTV and access control: the extra checks
- Surveillance Camera Code of Practice. Under the Protection of Freedoms Act 2012, relevant authorities, including all local authorities in England and Wales, must have regard to the code's 12 guiding principles. Principle 8 asks operators to consider approved standards, including for installation and maintenance, and to seek certification. Other operators are encouraged to adopt it.
- Chinese-made cameras. In November 2022, government departments were told to stop deploying visual surveillance equipment made by companies subject to China's National Intelligence Law on sensitive sites. A November 2025 update said the sensitive government sites originally identified had finished replacement work. This covers government sites, but NPSA points other concerned organisations to its procurement guidance, so some buyers may ask which brands you use.
- Cyber security. Networked cameras and door controllers often sit on the buyer's network. See Cyber Essentials for public contracts.
- Monitoring. If you watch cameras for a client, as well as maintaining them, check whether your staff need SIA licences.
What a strong bid shows
- Certificates in date for every scheme the specification names.
- Response times you can meet, including out of hours.
- Records the client can use. Responsible persons must record fire safety arrangements, and attempts to access flat entrance doors must be recorded. Show how your reports help.
- Brands you can maintain. Some lots ask for a panel manufacturer's approval, or equivalent.
- Insurance and turnover at the levels asked. See insurance and turnover requirements.
Practical steps
- List the systems you already service and match each to a scheme in the table above.
- Get third-party certification for your main service line before you bid on larger contracts.
- Register on the central digital platform and local buyers' supplier portals.
- Watch for framework renewals and preliminary market engagement notices, and respond to them.
- Target lots that match your trade, such as extinguishers or fire door inspection, instead of whole-building packages.
- Offer to subcontract to larger FM firms holding public contracts. See subcontracting on public contracts.
BidTrowel lists open fire and security contracts at /tenders/fire-security/ and can email you new ones.
Frequently asked questions
Do I need BAFE to service fire alarms for a council?
Not by law. But many buyers ask for BAFE or an equivalent, and without one you may fail a pass or fail question.
Who can do the quarterly fire door checks in flats?
Government guidance says the basic regulation 10 checks do not need a specialist, so trained caretakers or maintenance staff can do them. Repairs and replacements must be done by a competent person, which is where specialist firms come in.
How often should a fire alarm be serviced?
BS 5839-1:2025 says about every 6 months, with any visit between 5 and 7 months after the last one acceptable. The site should also test the alarm weekly.
Can I win security contracts without NSI or SSAIB?
Yes, where the buyer does not ask for it. But for alarms with police response, NSI and SSAIB both link their certification to URN eligibility.
This guide is general information, not legal advice.
Sources
- legislation.gov.uk: Regulatory Reform (Fire Safety) Order 2005, article 17 (checked 28 October 2026)
- GOV.UK: Fire safety in the workplace: who's responsible (checked 28 October 2026)
- London Fire Brigade: Changes to fire safety law and how it affects you (checked 28 October 2026)
- GOV.UK: Fire Safety (England) Regulations 2022 (checked 28 October 2026)
- legislation.gov.uk: Fire Safety (England) Regulations 2022, regulation 10 (checked 28 October 2026)
- GOV.UK: Fact sheet: lifts and essential fire-fighting equipment (regulation 7) (checked 28 October 2026)
- GOV.UK: Fire Safety (England) Regulations 2022: fire door guidance (checked 28 October 2026)
- GOV.UK: Criteria for being a higher-risk building during the occupation phase (checked 28 October 2026)
- GOV.UK: A guide to making your small non-domestic premises safe from fire (2024, PDF) (checked 28 October 2026)
- Fire Industry Association: Guide to the changes in BS 5839-1:2025 (PDF) (checked 28 October 2026)
- IET Wiring Matters: Key changes to BS 5839-1:2025, part 2 (checked 28 October 2026)
- Fire Safety Matters: Updated BS 5266-1 issued by BSI (checked 28 October 2026)
- NICEIC: BS 5266-1 emergency lighting (checked 28 October 2026)
- BAFE: How often should I be servicing my fire extinguishers? (checked 28 October 2026)
- BAFE: Become BAFE registered (scheme list) (checked 28 October 2026)
- BAFE: Dry riser and wet riser servicing (checked 28 October 2026)
- BAFE: Fire risk assessment (SP205) (checked 28 October 2026)
- NHS England: HTM 05-03 Part B, fire detection and alarm systems (PDF) (checked 28 October 2026)
- BSI: BS 8674:2025, framework for competence of individual fire risk assessors (checked 28 October 2026)
- IFE: Update on new BS 8674 standard (checked 28 October 2026)
- Specification Online: FDIS achieves UKAS accreditation for fire door inspectors (checked 28 October 2026)
- BM TRADA: Q-Mark fire door maintenance scheme (checked 28 October 2026)
- Kiwa: IFC Certification installer schemes (checked 28 October 2026)
- Fire Safety Search: Warringtonfire celebrates 30 years of FIRAS (checked 28 October 2026)
- FPA: Updating LPS 1048 (checked 28 October 2026)
- NSI: What is the difference between Gold and Silver certification? (checked 28 October 2026)
- NSI: Your workplace FAQs (checked 28 October 2026)
- NSI: NPCC releases 2025 policy update for police response to security systems (checked 28 October 2026)
- SSAIB: Schemes and SSAIB: Specifiers (checked 28 October 2026)
- West Yorkshire Police: Alarms policy (checked 28 October 2026)
- GOV.UK: Amended Surveillance Camera Code of Practice (checked 28 October 2026)
- GOV.UK: Surveillance Camera Code of Practice: a guide for local authorities (checked 28 October 2026)
- NPSA: Security update on surveillance equipment (24 November 2022) (checked 28 October 2026)
- Parallel Parliament: Written statement HCWS386, Security update on surveillance equipment (checked 28 October 2026)
- Parallel Parliament: Written statement HCWS1065, China-manufactured surveillance equipment: sensitive sites (18 November 2025) (checked 28 October 2026)
- GOV.UK: Licensing requirements for the use of CCTV (FOI release) (checked 28 October 2026)
- Find a Tender: University of Strathclyde, fire alarm, EVCS and extinguishing systems maintenance contract notice (checked 28 October 2026)
- Find a Tender: Royal Holloway, security systems maintenance preliminary market engagement notice (checked 28 October 2026)
- CPC: Fire safety equipment, fire alarms, suppression systems and associated services (checked 28 October 2026)